A battery starts with amps not volts. Please explain what you mean by 'won't start': will the starter turn at all or is it all completely dead? The more I read about fuel solenoid the more I think my tractor non-run problem may be related to the fuel solenoid. Press J to jump to the feed. I did try the fuel solenoid after I removed it and the rod does not move when starting the tractor. What this does is, it pulls the fuel and takes it to the engine from the fuel tank. To fix this problem, you need to lean the fuel bowl first. if it is good, in other words it doesnt drop below about 11 volts. For almost a Month I could not start the Kubota Tractor, come to find out after testing every switch and relay on the tractor it is a plunger switch on the what Kubota calls the (speed control pedal in the owners manual) (they should call it the Forward/Reverse pedal) Translators ? Established in 2009, we are the largest online community of Kubota tractor and equipment owners. Any chance a pto is engaged? Read somewhere that the fuel solenoid can cause the issue. Charged the battery, check the continuity on the fuses, traced power to the starter Ask an Expert Car Questions Agriculture and Farm Equipment Is the concern it will not crank or it will not start? What does hang up is the PTO safety hookup on the PTO lever itself ( right side of wheel). Today went to start the tractor and it won't start. You must log in or register to reply here. what does the volt meter say when you try to start it. When you load heavier the RPM shows down to an almost shiftless situation. Press J to jump to the feed. If it's got 12v at battery but no instrument panel lights, I'd suspect the switch. Firstly, check the fuel line. Replace the oil with some light oil. I can't get back to it right now, but I'll have a chance to take another look at it Sunday afternoon and I'll try all your suggestions. You must log in or register to reply here. This way you will get to know if the battery is dead. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. It will have issues over time as it is made for heavy-duty work. Secondly, check and inspect the fuel filter. Or maybe one of the PTOs are engaged? tank is 3/4 full, new fuel filter, my fathers friend came over and sprayed diesel in the intake and it started running a bit but soon as he stopped, engine stopped. then put the leads on the clamp connections and read it there. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. Checked battery, fuses, fuel and all are good. The dash lights stay strong and do not dim when the key is turned. So, you need to check the battery first if you are facing this kind of problem. For a better experience, please enable JavaScript in your browser before proceeding. 250 an hour?!? Definitely sounds like a fuel pump issue. JavaScript is disabled. If you are facing any of those, do not worry. Luckily, all these parts are much less money than just one hour of labor. My Kubota l3400 tractor won't start. Or your fuel system needs bleed out so leave the injector line loose and crank for a while. So run the battery voltage test again. At the end of the fuel rail is a valve. Do it again if you feel needed. It drives power from the tractor to the PTO-driven machine. If the diesel fuel pours as it leaves the line, there may be something clogged in the line. Turned on the engine and let it idle for a few minutes until it sounded better. Kubota L3400 tractor overview. 61. But what is the problem which can appear in front of you? After that, it will pick it up in about a minute or so. The first time it happened, it was 10 minutes before I figured it out. JavaScript is disabled. Join us in searching for a Kubota diesel that will not start in the cold weather. I am thinking maybe the ignition switch? Here are the symptoms: It could still be the battery. The hold in coil is usually tied into low oil pressure, high temperature, sensors to shut the engine down if there is a problem develop when it's already running My 3400 HSt was new in dec 2006 and recently developed an intermittent starting problem, sometimes it would go etc.. This happens infrequently enough for me to forget each time, and I just sit there with a puzzeled look on my face for about 30 seconds. Kubota L3540 Won't Start. We and our partners use cookies to Store and/or access information on a device. else. L3450DT-GST, Woods FEL, B7100 HSD, FEL, 60" SB, 743 Bobcat with V2203, and more. JavaScript is disabled. There can be a malfunctioning steering hydraulic cylinder that can cause the problem. Got up the next day, no start. Thank you Wolfman. Mine has a switch for each of the two gear shift levers. The dash lights come on, but when I turn the key all the way there is no click or response at all from the starter. if it is good, in other words it doesnt drop below about 11 volts. Once i had it running with the fuel solenoid out I had to get the tractor to turn off so I engaged it into gear and stood on the brake which shit the tractor off. This sub Reddit is meant for everything and all things tractor and tractor related things. If not the you have your culprit. Create an account to follow your favorite communities and start taking part in conversations. If voltages are all good when attempting a start, but starter will not engage, then battery voltage is not getting to the starter or the return path is high resistance/open. if its filled with dirt and thick mud-like object, you need to replace the filter. Try what RockyRidge said, rock the HST pedal "sloooowly" with the key in the start positionmy L2800 used to do this fairly regularly and no it will not fail for the dealer if it is like mine it will get better, I haven't had to rock my pedal in many months. If it is, you need to replace it. Turn the dial to the lowest setting in the resistance mode in the ohms portion of the meter. Press question mark to learn the rest of the keyboard shortcuts. Crack a line at an injector and see if you have fuel when cranking the engine. if it is very low there, then by all means clean/repair the connections. It was fine then. If there is any water mixed with the oil then the engine can stall. Replaced the stop relay but still get same results. it should do the work. if your Kubota tractor won't start watch this video - and try this first. The issue is most likely another safety switch. Another common problem in Kubota is not getting started at all but just clicking. Fuel tank is half full. Closed the air vent cock. Just a wild guess though. Spray DW40 on the rubberboot and work the PTO shift back and forth. Battery is good. After that, check the voltage of the battery. Kubota L3400DT-IF 4 WD Tractor, Serial . For a better experience, please enable JavaScript in your browser before proceeding. You must log in or register to reply here. Put the solenoid back on and it would start but then die immediately. Charged the battery, Charged the battery, check the continuity on the fuses, traced power to the starter read more Chris (aka-Moose) Technician 363 satisfied customers 2015 Kubota 3350 w/cab . I figured I needed to bleed the system. If so then it could be a filter but not likely. If this is HST, rock your forward/reverse pedal back and forth while holding the key in the crank position. Check if it is dead or have any other problem. If not try the second one. so look for bad grounds. Then check the wiring. Best Evergreen Trees to Plant In New York, 10 Evergreen Trees to Plant in North Carolina, 5 Common Problems with John Deere 4120 (Solutions Included), Most Common Problems with John Deere 5045E (Solutions Added), 6 Most Common Problems with Massey Ferguson 240, 5 Most Common Problems with Bobcat T770 (Solutions Included), Most Common Problems with John Deere 750 (Solutions Added). Separating Rear Axle Case from Brake Case, Manual Transmission and Glide Shift Transmission, Double Acting Type 2 (Floating with Detent), Electronic Instrument Panel (Intellipanel), Testing, Setting and Adjusting by Electronic Instrument Panel (Intellipanel), Checking GST Electric Control System (GST Model Only), Air Conditioner Relay, Blower Relays and Compressor Relay, R134A Refrigerant Recovery and Recycling Machine, Air Conditioner System and Front Windshield Wiper10-S31, Disassembling Differential Gear Assembly (L2800), Disassembling Differential Gear Assembly (L3400), Checking High Pressure Relief Valve Pressure, Separating MID Case from Transmission Case, Hydraulic Pump Test Using Flow-Meter (Power Steering), Hydraulic Pump Test Using Flow-Meter (Three Point Hydraulic System), Relief Valve (for Three Point Hydraulic System), Hydraulic Pump (Three Point Hydraulic System), Kubota L3400 Operator's Manual (94 pages), Care of Danger, Warning and Caution Labels, Instrument Panel, Switches and Hand Controls, Foot and Hand Controls (Manual Transmission Type), Warm-Up Transmission Oil in the Low Temperature Range, Do Not Operate the Tractor at Full Speed for the First 50 Hours, hangssig Lubricating Oil for New Tractors, Travel Adjustment/Suspension Adjustment Knob, Head Light/Turn Signal/Hazard Light Switch, Main Gear Shift Lever & Range Gear Shift Lever [Manual Transmission Type], Range Gear Shift Lever (L-M-H) [HST Type], Unlock the Parking Brake and Slowly Release the Clutch, Depress the Speed Control Pedal [HST Type], Make Preparations for Attaching Implement, Hydraulic Control Unit Use Reference Chart, Liquid Weight Per Tire (75 Percent Filled), Cleaning Grill, Radiator Screen and Oil Cooler, Checking Gauges, Meter and Easy Checker (TM), Cleaning Air Cleaner Element [Single Element Type], Replacing Hydraulic Oil Filter/Replacing Transmission Oil Filter [HST Type], Checking HST Oil Line [HST Type]/Checking Power Steering Line, Every 800/1500/3000 Hours and Every 1/2 Year, Flush Cooling System and Changing Coolant, Handling Precautions for Electrical Parts and Wiring. Welcome. It's diesel so it's probably either the injection pump or the lift pump. .Sometimes it starts, then dies. Checked battery, fuses, fuel and all are good. My relatively new (71 hours) Kubota L3400 will not start. I got the tractor to start and it ran fine. That isn't an issue. Not starting, shutting off after some time, POT not turning on, and RPM slowing down are the common kubota l3400 problems. If not then your solenoid could be bad if so then you have bigger issues that need deeper troubleshooting. if it is very low there, then by all means clean/repair the connections. Check the gear compartment if something like stone or dried mud had stuck there. Fix all the connections battery has with other parts of the vehicle. You can also do a Biocide treatment and set it for overnight. The ignition lights and dash lights turn on with the key on but the engine does not turn over. Open it, start it and let it run for a few minutes then close it. Thanks to all of you who responded. I disconnected the two wires and plugged them into themselves and it started right away now it doesn't turn over at all. Or if there is any faulty safety switch, it needs to replace too. Is your 3400 a hydrostat or standard shift transmission? Was asked to take a look at this problem and was solved by installing Starter Relay Kit That he bought from john deer but will work on any tractor I would think. Pulled fuel cut off solenoidstarts. Don't really have that for something that doesn't get used much. For a better experience, please enable JavaScript in your browser before proceeding. You are using an out of date browser. I am going to talk about it elaborately in this article. Though it is a renowned brand, unfortunately, there are some problems you may face. 62. You are using an out of date browser. Sounds like an obstruction or bad lift pump. Did you run it out of fuel? If the problem does not solve yet, replace the fuel filter. Or bad battery connection(s). 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. kubota L3500 cranks but won't start (EDIT) not 3500, L3400, and i think he said it was a 2008 model. If your Kubota diesel engine does not start, begin by confirming that your electrical and fuel delivery systems are performing properly. Any thoughts? Fuel tank is half full. Injection pumps rarely fail. To know in detail, read on. You're not getting fuel to START the machine because they tie that pull in coi l into the safety switches in the START circuit. Thats usually me. Kubota L3400 starter won't engage. Most times I get no click from the solenoid. This problem occurs mostly with heavier loads. what I found was that not enough. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. It may not display this or other websites correctly. They wanted 110ish for the shop manual for my L2501. Put new solenoid on.no start. I always heard a click when when I turned on the key. My Kubota l3400 tractor won't start. Disconnect the line which connects the fuel filter and the fuel pump. Reading battery voltage with no load, does not tell the whole story. I got this tractor from my grand father that passed last year, about 2800 hours on it, my fathers friend helped tow it over and has been sitting beside the RV under our car part since, it has been ran a few times with no issues. It is hard to believe that two little wires control the whole contraption. Still no idea what to do next. Both have to be in neutral. Thats where I would start, back on the battery. Removed the solenoid and the tractor started, had to restrict airflow since the fuel solenoid was not connected.. As it is a motor device, having problems from time to time is not uncommon. The fuel solenoid shuts off fuel or engages linkage that controls fuel distribution. After some time, this cycle will start all over again. Kubota has no idea what it is, and i'm not going to the place that gave me that quote, we jumped it for now. To test circuits, fuses and switches use a multimeter tester you can get one here: http://amzn.to/2A5ihXN , you check continuity of circuitssimple example: if you have a standard fuse you put the test wires on either end if fuse is blown it wont show on your meter, if its good needle will go up showing that current can flow through it(Continuity) if your multi-meter doesn't have a dedicated continuity test mode, you can still perform a continuity test. 63. Tight and clean them if necessary. It generally happens when algae grow inside the fuel bowl. Hey guys. It may not display this or other websites correctly. From what you've posted thus far I'd leave the switch alone and start thinking the fuel shutoff solenoid (""it isn't clicking") is bad. I don't recall the deadman switch working like that, I thought it would only stop the engine if the tractor was moving. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. The Shuttle Shift lever is stuck in the middle- it will not go into H/L/Reverse. L3400DT W/ LA463 FEL and L235DT W/ BF400 Loader. You can find it by following the fuel line back from the injection pump and the first thing you run into with wires is likely the lift pump. It should solve the problem. You must log in or register to reply here. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. Sometimes it well run for a few seconds other times a few minutes. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. Today went to start the tractor and it won't start. Anything and everything about Kubota. Aug 9, 2021. Do it for at least fine munities. called kubota and other parts places, they have no idea what it is, can't find a pic of it anywhere, so we just put a switch on it for now. Fuel flow issues are the most common reason for Kubota L3400 to stop working after running for a while. Kubota is a brand of tractor that is very much reliable for many kinds of agricultural work. Do they at least give you a reach around? Here are some of them you can face with the solution with it. The dead man switch on my fwd/rev pedal is 100% my culprit for no crank no start. You have found you high resistance problem. For a better experience, please enable JavaScript in your browser before proceeding. Welcome. Many thanks. Dead battery? Battery is good. If it is the starter solenoid circuit that is preventing the starter, you can activate the starter at the starter, by bypassing the interlocking safety switches and activating it directly at the starter. As we also learn about what makes them so reliable, and how to properly start and take care of your small. Manage Settings The fuel solenoid is not engaging. Battery fully charged, Curtis B., Technician 44,329 Curtis B., Technician 44,329 Satisfied Customers Removed the solenoid and the tractor started, had to restrict airflow since the fuel solenoid was not connected.. It could be your fuel pump, but more likely it's your solenoid. Can it be solved at home? Not being able to use any particular gear is not a common problem, but it occurs sometimes. Try cleaning your battery post and ground cable. Fuel flow issues are the most common reason for Kubota L3400 to stop working after running for a while. THe tractor will turn over but will not start. Why is the steering wheel spinning very easily? But since your relays may not even click. If it's the fuel shut off, disconnect it or block the thing so it will not shut off the fuel. Evacuator Valve. Lights can still work with a dead (actually low voltage) battery. The other switches to look for are on the clutch pedal, on the range shifter if it is a standard shift or one just above the center of the floor board if it is a hydrostat. With the wires plugged into each other you have the tractor thinking that the PTO is always disengaged, therefore it will start with the PTO engaged. LOL. There are 2 coils in there and when the switch is the start position, it puts power to the "pull in coil", when the switch drops into the run position it moves the current to the "hold in coil". 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. Check that the fuel shutoff solenoid is getting voltage before you go blaming the pump. Yes, if the air was formed in the hydraulic system, it can be stopped completely. If its still on, check for the cable which runs from the PTO shift and goes into the transmission case under the seat. Kubota Tractor Don't Start? i even bushogged with it for 3 hours. Mechanic's Assistant: What is the complete model and serial number of your machine? It may not display this or other websites correctly. 64. Curious is you got this resolved and if so, how? What happens here is, that every other gear works fine and when you try to use that particular gear. RUBYRUSS only posted a day ago that there was a problem with his L3200. tested the solenoid and it works. Last week i got it out to pull a small tree and did great, put it back under the car port, came back the next day, started right up, drove about 50feet and quit, the engine turns over fine, but won't fire. Standard Transmission. I had it going on Wednesday for about 20 to 30 minutes pushing snow, and then came back a few hours later to do some more work, and it wouldn't start. Kubota enthusiasts, hobbyists, and fans! You must log in or register to reply here. The ignition lights and dash lights turn on with the key on but the engine does not turn over. . Kubota is one of the most reliable agricultural vehicles to choose from. Why is my diesel engine stalling in Kubota L3400? Established in 2009, we are the largest online community of Kubota tractor and equipment owners. shut down tractor in field, We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. 63. 1. Kubota L3400 is a farmers tractor which is a very vital part for some of them. Not the clamp connections, directly on the post's have someone try to start the tractor, anything less than 10.5 or 11 volts indicates either a bad battery (high internal resistance, or sulphated) or a shorted/draggy starter. I'm smart and relatively mechanically inclined, but I don't have a lot of experience with diesel or tractors, much less diesel tractors. I tried the solution proposed by crbr, rocking the transmission pedal - and it worked - made my day! OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. then put the leads on the clamp connections and read it there. But today when I turned the key to start, no click, only the sound of the starter turning. You are using an out of date browser. (EDIT) not 3500, L3400, and i think he said it was a 2008 model. Put the solenoid back on and it would start but then die immediately. Buts that's where the real. I disconnected the two wires and plugged them into themselves and it started right away now it doesn't turn over at all. You need a multimeter to start checking voltages. / Simple Trouble Shooting RudydaGoat 163 subscribers Subscribe Share 54K views 3 years ago Just on that one mission i learned lots. Checking Engine Start System. Nonetheless, I'm the man of the farm, so this repair falls on me. It generally happens if there are any battery issues. If not, try to see a professional who can fix the problem for you. Unfortunately, not all tractor is perfect. Is the large wire on the starter near 12.6 volts?
Power Bi Subtract Two Columns From Different Tables, Think Tank Internships Summer 2021, Articles K
Power Bi Subtract Two Columns From Different Tables, Think Tank Internships Summer 2021, Articles K